  • 医院手术室如何将作用大化利用
    来源:http://www.moptuan.com 浏览: 发布日期:2017-10-16
    医院是病毒比较多的地方,各种细菌交叉感染有可能导致进入人体体内,危害人体健康。那么怎样加强医院手术室的净化工作呢,是不是很想知道,来,净之源来告诉你。
    The hospital is the place where the virus is more, all kinds of bacteria cross infection may lead to enter the human body, endanger human health. So how to strengthen the cleaning work of hospital operation room, is not very want to know, to tell you the perfect health.
    医院手术室净化是外科诊治和抢救病人的重要场所,是医院的重要技术部门。各种医疗部门的医疗设备都发挥着重要的作用。首先要每天保持手术室的清洁卫生。经常用消毒水和洗涤剂清理地面和墙壁,打扫完毕后一定要打开窗户,使室内彻底通风。
    Hospital operation room purification is an important place for surgical diagnosis and treatment of patients, and is an important technical department of the hospital. Medical equipment in various medical departments plays an important role. First of all, keep the operation room clean and hygienic every day. Clean the ground and wall with disinfectant and detergent, and open the window after cleaning, so that the room can be completely ventilated.
    这样做的目的是杀菌消毒,有效防止细菌的增生和繁衍。重要的一点是加强手术器械的消毒和净化。首先要把器械上的血迹清洗干净,一定要用留守冲洗。医用缝合针、医用手术刀片,直接扔掉不再利用。然后要彻底的检查手术器械。如果发现有不合格的,应及时剔除。后将合格的器械,送入超声波清洗器,震荡清洗,风干。
    The purpose of this is sterilization, and effectively prevent the proliferation and reproduction of bacteria. The most important point is to strengthen the disinfection and purification of surgical instruments. First of all, to clean the blood on the instrument, we must use left behind flush. Medical suture needle, medical surgical blade, directly thrown away, no longer use. And then thoroughly examine the surgical instruments. If found unqualified, should be promptly removed. Finally, the qualified instruments are sent to the ultrasonic cleaner, and the vibration is cleaned and dried.
    医院手术室是细菌滋生多的地方,也是人流量大的地方。请及时做好手术室的净化工作。为自己负责,为他人负责。
    Hospital operation room is the most bacteria breeding place, but also the largest flow of people. Please do the operation room cleaning work in time. Be responsible for yourself and responsible for others.
    医院手术室设计的新观点, 高等级手术室空调体系宜独立设置。所谓手术室净化工程是指千级以上手术室,其原因是高等级手术室空调送风量大,如相同面积的手术室,百级手术室的空调风量是十万级的3.4倍,是万级的2.25倍。
    The new viewpoint of operation room design in hospital, the air conditioning system of high grade operation room should be set independently. The so-called operation room purification engineering refers to 1000 above the operation room, the reason is the high level of operation room air volume in the same area, such as the operation room, operation room 100 air volume is 3.4 times one hundred thousand, 2.25 times the million level.
    别的高等级手术室的运用频率远低于低等级手术室,这么不管是一个空调体系担负多个高等级手术室,或是一个空调体系担负一个高等级手术室和多个低等级手术室,都会使空调体系长时间处于"大马拉小车"的运转状况。
    The frequency of other high level is far lower than the low level of operation room operation room, so whether it is an air conditioning system for a number of high-grade operation room, or an air conditioning system for a high level and a low level of operation room operation room, will make the air conditioning system for a long time in the "big car Mara" operation.
    层流手术室装修
    例如一个空调体系担负1间百级手术室和2间万级手术室或4间十万级手术室,只需高等级手术室不运用,则体系规划风量少大于此刻所需风量的112%和84%,手术室净化工程亦即此刻体系所需风量仅为体系规划风量的47%和54.3%.
    For example, an air conditioning system for 1 100 and 2 000 operation room operation room or 4 grade one hundred thousand operation room, operation room only high grade is not used, the system planning volume at the moment at least greater than the required air volume of 112% and 84%, which is now the operation room purification engineering system of the required air volume is only 47% and the air volume system planning 54.3%.
    并且此种因手术室运用与否引起的风量改变,不宜选用变频调速方法进行调理,只能用调理总风阀的方法调理风量以习惯体系风量改变,但是此种方法明显不节能。所以不管从节约能源的视点,或是从运用可*性、灵活性的视点,高等级手术室都应"按间"独立设置空调体系,即一个净化空调体系对应一间手术室。
    And the air for operation room use and not caused by change, should not use the frequency control method of conditioning, can only use the method of conditioning air valve air conditioning total change to customary system volume, but this method was not such. Therefore, no matter from the point of view of energy conservation, or from the use of flexibility, flexibility point of view, high-level operation room should be "according to the" independent set up air-conditioning system, that is, a clean air conditioning system corresponding to a operation room.
    关于低等级手术室,虽然与高等级手术室比较空调风量小的多,但一个空调体系所担负的手术室间数也不宜过多,由于手术室净化工程医院手术室的运用状况具备不确定性。愈是高等级医院,手术室为满足特别繁忙状况,设置愈多。
    A low level of operation room, although compared with the high level of operation room air volume is small, but for an air conditioning system of the operation room room number should not be too much, because of the use of purification for operation room hospital operation room with uncertainty. The higher the level of hospital, the operation room in order to meet the special busy situation, the more settings.
    手术室多,正常状况下的一起运用系数低,这么当一个空调体系所担负的手术室间数较多时,体系常处于"供大于求"的状况,其运转能耗势必较高,就象有的医院所反映的"建的起,用不起"。笔者以为,关于低等级手术室一个空调体系所担负的手术室不宜多于四至五间,并且一个体系担负手术室过多,也会形成运用上的不行。
    Operation room, under normal conditions with the use factor is low, so when taking an air conditioning system in the operation room room number is large, the system often is in oversupply situation, the energy consumption is high, as some hospitals reflect "built up, can not afford". The author believes that the operation room of an air conditioning system for low grade operation room should not be more than four to five, and a system responsible for the operation room too much, but also the formation of the use of not.
    以上文章来源于手术室装修http://www.moptuan.com

    上一篇:洁净手术室装饰材料的选择
    下一篇:无尘车间防火措施怎么做好呢?