  • 重症监护室内的供氧系统设计方案都有哪些?
    来源:上海11选5走势图http://www.moptuan.com 浏览: 发布日期:2019-12-30
    材料和工具:煤气管道采用脱脂红铜管或304不锈钢管;病房设备主要包括铝合金设备带、医用气体终端;安装工具需准备管道焊接设备(铜管一般采用气焊、氧气+气体或氧气+乙炔)(不锈钢管一般采用二氧化碳焊接、焊机+气体)、焊接带枪及劳动保护工具;铝机、锤、钻、钳子板等手工工具。
      Materials and tools: degreased red copper pipe or 304 stainless steel pipe is used for gas pipeline; ward equipment mainly includes aluminum alloy equipment belt and medical gas terminal; pipeline welding equipment (gas welding, oxygen + gas or oxygen + acetylene are generally used for copper pipe) (carbon dioxide welding, welding + gas are generally used for stainless steel pipe), welding gun and labor protection tools; aluminum machine, hammer, drill Pliers board and other hand tools.
      一、医院供氧系统管网材料介绍
      1、 The introduction of materials for the pipe network of oxygen supply system in hospital
      氧气管道的铺设和安装顺序可根据现场实际情况进行。一般采用外径为8mm-133mm的主管和支管。
      The laying and installation sequence of oxygen pipeline can be carried out according to the actual situation on site. The main pipe and branch pipe with the outer diameter of 8mm-133mm are generally used.
      规范的设计主要供氧管道:管道在病房主楼有超过1000个床位应大于50毫米,超过500个床位的主要管道应大于25毫米,和超过100个床位的主要管道应当大于16毫米;
    重症监护室装修
      The main oxygen supply pipeline center of the standard design: the pipeline in the main building of the ward with more than 1000 beds should be greater than 50 mm, the main pipeline with more than 500 beds should be greater than 25 mm, and the main pipeline with more than 100 beds should be greater than 16 mm;
      供氧支管(各层走廊)规范设计:100层以上支管大于16mm, 50层以上支管大于12mm;
      Standard design of central oxygen supply branch pipe (corridor on each floor): the branch pipe above 100 floors is more than 16mm, and the branch pipe above 50 floors is more than 12mm;
      进病房氧气管道规格:一般根据气体终端接口采用6mm-10mm管道;
      Specification of oxygen pipeline entering the ward: 6mm-10 mm pipeline is generally adopted according to the gas terminal interface;
      医院供氧管道的设计与安装
      Design and installation of oxygen supply pipeline in hospital
      1. 医用燃气管道与管道外缘及附件之间的距离不得小于25mm,并需进行维护;
      1. The distance between the medical gas pipeline and the outer edge and accessories of the pipeline shall not be less than 25 mm, and maintenance is required;
      2. 医用燃气管道与其他管道之间的小间距规定如下(图)。在没有隔离措施时,应采取适当的隔离措施。
      2. The small spacing between medical gas pipeline and other pipelines is specified as follows (Figure). In the absence of isolation measures, appropriate isolation measures shall be taken.
      3.管道安装、焊接完毕后,应清洗管道内壁。
      3. After the installation and welding of the pipeline, the inner wall of the pipeline shall be cleaned.