  • 层流手术室设计装修前的建设很重要
    来源:http://www.moptuan.com 浏览: 发布日期:2017-07-04
    要做好层流手术室装修,就需要在方案设计论证时能保证功能合理,有足够的层高,层面设备部位承重等合理设计。在土建施工时应该预留洞口、预埋工作、防水层施工等工作。总包单位安装施工时应进行总体的科学规划,统筹安排各专业承包单位、其他配合单位。
    To do a good job in laminar flow operation room decoration, it is necessary to ensure reasonable function in the design and demonstration of the program. There is a reasonable design of high storey, level equipment, parts bearing and so on. In the civil construction, the openings, burial work and waterproof layer construction shall be reserved. In the installation of the general contractor, the overall scientific planning shall be carried out, and all the specialized contracting units and other cooperative units shall be arranged as a whole.
    合理设计是实现层流手术室装修建筑节能的主要途径。设计方的设计图纸深度要具备施工要求。医院层流手术室设计首先是工艺设计,医院建筑与普通民用建筑,存在的大区别就是医院功能复杂、流线复杂。层流手术室设计首先是工艺设计,然后才是建筑设计。符合洁净规范要求的、布局合理的平面布局确定后,再进行洁净空调、装饰装修、医用气体、电气、给排水等专业设计,满足功能需求,安全、方便,是一名设计师必须考虑的问题。
    Rational design is the main way to achieve energy saving in laminar flow operation room. The design drawings of the designer shall be provided with construction requirements. The design of laminar flow operation room in hospital is the first process design. The biggest difference between hospital building and ordinary civil building is the complicated function and complicated streamline of the hospital. Laminar flow operation room design is the first process design, and then architectural design. Meet the requirements of the clean layout and reasonable layout is determined, then the clean air conditioning, decoration, medical gases, electrical, drainage and other professional design, to meet the functional requirements, safe and convenient, is a designer must consider the problem.
    层流手术室装修
    洁净手术部功能布局是基础,洁净手术部由层流手术室和为手术室服务的辅助功能用房组成。洁净手术部应自成一区,并宜与其密切相关的外科护理单元临近,应严格分为洁净区与非洁净区,洁净区与非洁净区之间必须设置缓冲室或传递窗。洁净区内宜按对空气洁净度级别的不同要求分区,不同区之间宜设置分区隔断门。
    The function layout of the clean operation Department is the foundation, and the clean operation Department is composed of a laminar flow operation room and an auxiliary function room for the operation room. The clean surgery department should be divided into clean areas and close related surgical care units, which should be strictly divided into clean and non clean areas, and buffer rooms or transfer windows must be provided between clean and non clean areas. The clean area should be divided into different partitions according to the air cleanliness level, and the partition doors should be set up between different districts.
    洁净区:各种等级的层流手术室、手术准备室、刷手间、无菌敷料和器械存放室、一次性物品和精密仪器室、恢复室、患者换车处、洁净走廊等。
    Clean area: all levels of laminar flow operation room, surgical preparation room, brush room, sterile dressing and instrument storage room, disposable articles and precision instrument room, recovery room, patient change department, clean corridor, etc..
    非洁净区:医生、护士值班室,示教室,敷料打包、高压消毒室,器械洁净清洗室,石膏室,冰冻切片室,换鞋、更衣、浴、风淋室。净化空调机组、手术特殊医用气体中心站和配电,一般应单独集中在一层(设备层)。
    Non clean area: doctor, nurse's duty room, clinic room, dressing package, hyperbaric sterilizer, instrument cleaning room, plaster room, frozen section room, changing shoes, changing clothes, bath, air shower room. The purification air conditioning unit, operation, special medical gas central station and power distribution should be centralized on the first floor separately (equipment layer).
    以上就是我们层流手术室装修的相关介绍,本文来源,更多精彩内容请点击:http://www.moptuan.com
    The above is our laminar flow operation room decoration related introduction, this article origin, more splendid content, please click: http://www.moptuan.com

    上一篇:层流手术室装修对各部位的装修要求
    下一篇:静脉药物配置中心布局的标准要求