  • 级层流手术室洁净空调设备的安装
    来源:上海11选5走势图http://www.moptuan.com 浏览: 发布日期:2017-07-17
    洁净空调系统为保证千级层流手术室整体控制的同时使各手术室灵活使用。所以对于一个大型医院,为满足各种手术的需要,手术室的数量较多,这就需要安装多个洁净空调机组。
    Clean air conditioning system in order to ensure the overall control of 1000 laminar flow operation room, while the operation room flexible use. Therefore, for a large hospital, in order to meet the needs of various operations, the number of operation room more, which requires the installation of more than one clean air conditioning unit.
    洁净空调机组一般应安装在与手术室毗邻的技术夹层内。为减少灰尘的来源, 应对技术夹层进行简单装修,对其地面要平整耐磨,水泥地面不起砂,有条件的可对地面采取贴地面砖等有效手段防止地面污染,顶与墙面应作涂刷处理。在设备安装前还应对技术夹层进行认真清理。
    The clean air conditioning unit shall be installed in the technical interlayer adjacent to the operation room. As a source to reduce dust, with sandwich simple decoration, on the ground to the formation of wear-resistant, not sand cement ground, conditional can take effective means affixed to the brick on the ground to prevent pollution of the ground, and the top wall should be brush treatment. The technical mezzanine should be carefully cleaned before the equipment is installed.
    层流手术室装修
    空气过滤器的安装是保证洁净度的重要的一个环节。我们在空气过滤器选型时均应采用一次抛弃型。
    The installation of air filters is the most important step in ensuring cleanliness. We shall adopt a throwaway type in the selection of air filters.
    洁净室通常是粗、中和三级过滤,系统中的中效过滤器安装在风机的正压段,过滤器安装在送风末端、回风口安装中效或粗效过滤器。粗、中和三级过滤器的安装位置直接影响洁净效果,安装人员在安装过程中一定要严格按照设计要求安装。
    Clean room is usually thick, medium and high efficiency filters, the filter system is installed in the fan of positive pressure, high efficiency filter installed in the air supply terminal, return air installation or coarse filter. Directly affect the installation position, and high third grade coarse filter cleaning effect, installation personnel in the installation process must be in strict accordance with the design requirements of installation.
    过滤器是千级层流手术室洁净空调系统的主要设备。由于滤纸非常精细,易损坏,因此只能在安装时现拆过滤器包装。过滤器安装时,施工人员除了要避免将其损伤外,还要注意安装时须将压紧螺栓拧紧,而且施力要均匀,另外,在边框搭接处封条应打入足够的密封胶,否则造成的泄漏将直接使千级层流手术室内洁净度超标。在系统试运转时,必须在进风口处加装临时中效过滤器作为保护。待试运转结束后,把临时中效过滤器拆下,换上过滤器运行。
    HEPA filter is the main equipment of the clean air conditioning system in the laminar flow operation room. Because the filter paper is very delicate and easy to damage, it can only be packed in an efficient filter at the time of installation. High efficiency filter installation, construction personnel in addition to avoid the damage, but also pay attention to the installation bolts shall be tightened, and the force should be uniform, in addition, in the frame of joint seals should be enough into the sealant, otherwise cause leakage will enable the 1000 class laminar flow surgery room cleanliness exceed the standard directly. In the system test run, the temporary air inlet filter shall be installed at the air inlet for protection. When the test run is over, remove the temporary intermediate effect filter and replace it with a high efficiency filter.
    本文由提供帮助,更多的相关内容请点击:层流手术室装修http://www.moptuan.com我们将详情为您解答.迎您的光临!
    This article provides the help, more related content please click: laminar flow operation room decoration http://www.moptuan.com, we will detail for you to answer. Welcome your presence!