  • 层流以及室内维持正压状态来维持的方式
    来源:http://www.moptuan.com 浏览: 发布日期:2018-04-09
      现代医院的中央空调系统本身就造成很大的污染隐患,对于医院内重要的功能科室,如手术部、ICU、CCU等,尽量做净化空调系统,通过物理过滤的方法,降低风管内的尘埃、细菌进入室内的风险。对于普通区域,推广使用带高效过滤器的风机盘管系统。

      The central air conditioning system of the modern hospital itself has caused a lot of pollution problems。 For the important functional departments in the hospital, such as the operating department, ICU, CCU and so on, we try to clean the air conditioning system。 Through the method of physical filtration, the risk of dust and bacteria entering the indoor air pipe is reduced。 For the general area, the fan coil system with high efficiency filter is promoted。

    上海11选5走势图  层流手术室的空调系统整体造价往往只占到特殊用房装修及安装(医疗设备除外)建设总费用的20-30%,装饰装修占30%-50%左右(主要是装修档次对造价影响较大),电气及智能化部分占到20-30%左右,医用气体、给排水及消防部分占到10%-20%左右。不能把建设医疗净化室的所有费用,都归结到“净化”方面。

      The overall cost of the air conditioning system in the laminar operation room is usually only 20-30% of the total cost of the special room decoration and installation (except for medical equipment), and the decoration and decoration is about 30%-50% (mainly affecting the cost of the decoration grade). The electrical and intelligent parts account for the left right of 20-30%, and the medical gas, water supply and drainage and fire control part account for 10%. About -20%. All expenses for the construction of medical purification rooms cannot be attributed to "purification".
    重症监护室装修

      进行层流手术室安装是创造洁净手术室的一种工程,无论它多么先进,但不能做到万能,很多人应该不知道层流系统是没有消毒灭菌功能的,层流手术室的环境是要靠人为的一些工作才能达成的,它要做到无菌环境主要是通过空气的过滤、层流以及室内维持正压状态来维持的。层流手术室安装后可以帮助手术室具有下面一些特点:

    上海11选5走势图  The installation of laminar flow operation room is a kind of project to create a clean operation room。 No matter how advanced it is, it can not be omnipotent。 Many people should not know that laminar system is no disinfection and sterilization function。 Air filtration, laminar flow and indoor maintaining positive pressure state are maintained。 Laminar operation room can help the operation room have some following characteristics after installation。

      1、科学净化杀菌,空气洁净度99.98% ;

      1, the scientific purification and sterilization, the air cleanliness 99.98%;

      2、层流手术室正压气流(+23-25Pa)感染率几乎为零 ;

      2, the positive airway pressure (+23-25Pa) infection rate in laminar operation room is almost zero.

      3、可供舒适的气流(室内温度可在15-25℃,湿度可在50-65%之间调节);

      3, for comfortable airflow (indoor temperature can be at 15-25 C, humidity can be adjusted between 50-65%).

      4、层流手术室低细菌数及低麻醉气体浓度;

      4, laminar flow operation room has low bacterial count and low anesthetic gas concentration.

      5、独特的设计使细菌无处藏身。

      5, the unique design makes the bacteria no place to hide。

      以上便是重症监护室装修今天的分享,您还满意吗,欢迎关注我们的网站:http://www.moptuan.com/并且关注我们的产品,我们将为您提供优良的产品,衷心的愿与您建立合作关系。

      The above is the sharing of the intensive care unit decoration today, are you satisfied, welcome to our website: http://www.moptuan.com/ and pay attention to our products, we will provide you with excellent products, and sincerely wish to establish a cooperative relationship with you.